{"id":468,"date":"2017-04-25T20:47:42","date_gmt":"2017-04-26T04:47:42","guid":{"rendered":"http:\/\/www.ecihvacllc.com\/?page_id=468"},"modified":"2026-07-17T16:09:56","modified_gmt":"2026-07-18T00:09:56","slug":"heat-pump-details","status":"publish","type":"page","link":"https:\/\/www.eciecad.com\/?page_id=468","title":{"rendered":"Heat Pump Details"},"content":{"rendered":"<blockquote>\n<h2><strong>SIDE DISCHARGE INVERTER HEAT PUMP PACKAGES<\/strong><\/h2>\n<\/blockquote>\n<ul>\n \t<li>2-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $12,622.98 + tax<\/li>\n \t<li>3-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $14,929.02 + tax<\/li>\n \t<li>4-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $17,129.71 + tax<\/li>\n \t<li>5-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $18,268.85 + tax<\/li>\n<\/ul>\n<!-- \/wp:post-content -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\"><!-- wp:list-item --><\/ul>\n<\/li>\n \t<li><em>R454B Refrigerant System &#8211; EPA Low GWP compliant product compact side discharge condensing unit with multi position air handler<\/em><\/li>\n \t<li><em>Hisense Extreme Heat &#8211; up to 88% of 47\u00b0F (8.3\u00b0C) rated capacity available at 5\u00b0F (-20 \u00b0C)<\/em><\/li>\n \t<li><em>ENERGY STAR and CEE North and South Tax Credit eligible<\/em><\/li>\n \t<li><em>NEEP Listed and Certified to CEE performance as a Cold Climate Heat Pump<\/em><\/li>\n \t<li><em>Achieve up to 100% capacity at 110\u00b0 (standard maximum operating range of 122\u00b0) and Heating Operation to as low as -13\u00b0F (-25\u00b0C)<\/em><\/li>\n \t<li><em>Improved indoor comfort by activating different compressor frequencies and indoor airflow modes for precise and intelligent control<\/em><\/li>\n \t<li><em>Quiet Operation: as low as 54dB on ODU<\/em><\/li>\n \t<li><em>Electric base pan heater installed standard<\/em><\/li>\n \t<li><em>Anti corrosion heat exchanger for extended life and increase performance<\/em><\/li>\n \t<li><em>Tested and rated to AHRI 210\/240-2023<\/em><\/li>\n \t<li><em>Multiple refrigerant leak alarms: Indoor A2L leak sensor on AHU and Outdoor shutoff and alarm for pressure drop<\/em><\/li>\n \t<li><em>Connect to all 24V thermostats (Nest, Ecobee, Honeywell) or Hisense Smart Thermostat with no adapter required<\/em><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<em><!-- \/wp:list-item --><\/em>\n\n<!-- wp:list-item -->\n<h3>What&#8217;s Included with Every Professional Installation<\/h3>\n<p class=\"isSelectedEnd\">Every installation is completed with high-quality materials and expert workmanship. Your installation includes:<\/p>\n\n<ul data-spread=\"false\">\n \t<li><strong>Up to 35 feet of refrigerant line set<\/strong><\/li>\n \t<li><strong>Communication\/control wiring<\/strong> between the indoor furnace or air handler and the outdoor heat pump<\/li>\n \t<li><strong>Equipment mounting pad<\/strong> with heavy-duty Sumo support blocks<\/li>\n \t<li><strong>Electrical whip, disconnect, and required fuses<\/strong><\/li>\n \t<li><strong>New base can and custom supply plenum<\/strong><\/li>\n \t<li><strong>Honeywell T9000 Smart Thermostat<\/strong><\/li>\n \t<li><strong>Honeywell F100 High-Efficiency Media Air Filter Assembly<\/strong><\/li>\n<\/ul>\n<h4>Furnace Installations Also Include:<\/h4>\n<ul data-spread=\"false\">\n \t<li>Indoor evaporator coil installation<\/li>\n \t<li>Exhaust venting for <strong>80% efficient gas furnaces<\/strong><\/li>\n<\/ul>\n<h4>Air Handler Installations Also Include:<\/h4>\n<ul data-spread=\"false\">\n \t<li><strong>5 kW to 7.5 kW electric backup heat strips<\/strong> for reliable supplemental heating during colder weather<\/li>\n<\/ul>\nWe take pride in delivering complete, code-compliant installations with premium components\u2014so your new comfort system is built to perform reliably for years to come.\n\n<!-- \/wp:list-item -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\"><!-- wp:list-item \/--><\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<!-- wp:list-item \/-->\n\n<!-- wp:list-item \/-->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\">\n \t<li style=\"list-style-type: none;\">\n<ul class=\"wp-block-list\"><!-- wp:list-item \/--><\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<!-- wp:list-item \/-->\n\n<!-- wp:list-item \/-->\n\n<!-- wp:list-item \/-->\n\n<!-- wp:list-item \/-->\n\n<!-- wp:list-item \/--><!-- \/wp:list --><!-- \/wp:list -->\n<ul class=\"wp-block-list\"><!-- \/wp:list --><\/ul>","protected":false},"excerpt":{"rendered":"<p>SIDE DISCHARGE INVERTER HEAT PUMP PACKAGES 2-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $12,622.98 + tax 3-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $14,929.02 + tax 4-TON SIDE DISCHARGE INVERTER A\/C WITH 80% GAS FURNACE OR AIR HANDLER INSTALL COST: $17,129.71 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-468","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.eciecad.com\/index.php?rest_route=\/wp\/v2\/pages\/468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eciecad.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.eciecad.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.eciecad.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eciecad.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=468"}],"version-history":[{"count":13,"href":"https:\/\/www.eciecad.com\/index.php?rest_route=\/wp\/v2\/pages\/468\/revisions"}],"predecessor-version":[{"id":1557,"href":"https:\/\/www.eciecad.com\/index.php?rest_route=\/wp\/v2\/pages\/468\/revisions\/1557"}],"wp:attachment":[{"href":"https:\/\/www.eciecad.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}